Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Impression Techniques and Misfit-Induced Strains on Implant-Supported Superstructures: An In Vitro Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 26 , Issue 4
July/August 2006

Pages 379–385


Impression Techniques and Misfit-Induced Strains on Implant-Supported Superstructures: An In Vitro Study

Murat C. Çehreli, DDS, PhD / Kıvanç Akça, DDS, PhD


PMID: 16939020
DOI: 10.11607/prd.00.0698

The purpose of this study was to compare misfit-induced strains on implant-supported superstructures fabricated by two impression techniques and two different elastomeric impression materials. A master cast hosting four Straumann implants was constructed. On this cast, a total of 21 implant-level impressions were made by the direct technique using a polyether impression material and synOcta screwed aluminum impression caps (PE-D), and by the indirect technique using polyether (PE-IN) or polyvinylsiloxane impression material (VPS-IN) with snap-on impression caps and synOcta plastic positioning cylinders. Two casts were randomly selected from each group of seven, and a total of four screw-retained superstructures, supported by either two or four implants (one of each type on both casts), were cast in a gold alloy for each group. Linear strain gauges were bonded on the superstructures, and misfit-induced strains were recorded during superstructure connection on each of the working casts and on the master cast using a data acquisition system and corresponding software at a sample rate of 10 kHz. Connection on the implants in the master cast increased strains considerably on most of the superstructures, in comparison with strain gradients measured when the superstructures were connected on the casts from which they were fabricated (P < .05). The differences in strain amplitude between connection on the cast from which the superstructure was fabricated and on the master cast were higher for superstructures fabricated by PE-D than for those fabricated by PE-IN and VPS-IN. The snap-on indirect impression technique for Straumann implants leads to acceptable superstructures, regardless of the impression material used. (Int J Periodontics Restorative Dent 2006;26:379–385.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help